Форум

Измеряй, Анализируй, Контролируй ... спрашивай, отвечай, советуй.

0
Отвечен

Conversion of pulses to water flow

tonio 8 месяцев назад в Общие вопросы обновлен Support Manager 8 месяцев назад 3

Hello! I have a D105 and I'm trying to connect the  water flow sensor YF-G1 to it, everythings ok, but i'm not really understanding the conversion from pulses to water flow.

Any helping in this matter?

0
Завершено

HOW-TO: Smart-MAIC D105 with Open Energy monitor sensor and Home Assistant

Mika 3 года назад в Советы и хитрости обновлен Support Manager 8 месяцев назад 3

Hello,

did lot of searching in Internet, but didn't find any guides how to set up Smart-MAIC D105 pulse counter with Home Assistant and Open Energy Monitor sensor. Open energy monitor is sensor that counts pulses from utility company kWh-meter and as such, it can be [legally] installed without being electrician and removing panels from electric cabinet (which I still did, as I needed to wire Cat5 for sensor neatly). It also shows exactly same consumption utility compay is charging, since it's read from "official" energy meter. Also, you may avoid need to re-seal electric cabinet, since installing measurement coils may require opening sealed cabinet parts.

My config in Home Assistant sensor.yaml is following:

- platform: mqtt
  name: "kWh-mittari"
  unique_id: 'smartmaic_myunitnumber'
  state_topic: "myunitnumber/JSON"
  unit_of_measurement : "kWh"
  device_class: energy
  state_class: total_increasing
  value_template: '{{ value_json.TCh1 | float * 0.001 }}'

My energy meter sends 1000 pulses for every consumed 1kWh, therefore, value template uses float * 0.001. Some meters use other values, like 800 pulses / 1 kWh, then this value template probably would be float * 0.0125. For this config to work, you need to:

1. configure MQTT server in your Home Assistant (I'm using Mosquitto)

2. configure MQTT in Smart-MAIC D105 (there's page for it)

With this config you can see hourly, daily, weekly, monthly etc consumption in your Home Assistant energy page. Add your electric price, it will count costs. When you adjust price, old values will be retained and only new consumption values get new price (likely higher...)


There's in no need to change default Smart-MAIC D105 pulse counter settings! Just make sure Mode of operation-setting is Pulse counter.


Open Energy Monitor-sensor is to be connected to digital input lines, with three wire:

- OpenEnergy Monitor red, VCC - Smart-MAIC contact 5

- OpenEnergy Monitor blue, TTL Data - Smart-MAIC contact 2

- OpenEnergy Monitor black, GND - Smart-MAIC contact 1

(This config is called NPN-counter in Smart-MAIC documentation)
There is no need to additional electronic components (resistors etc.). I'm using unshielded Cat5e as signal cable, sensor is about 15m from counter and works well with Cat5e. 

0
Отвечен

Is it possible to add frequency readings to dashboard?

Terry 8 месяцев назад в Дашбоард и виджеты обновлен Support Manager 8 месяцев назад 3

Frequency readings will be really useful not only for us, but for many clients. Thanks in advance

0
Отвечен

Is it possible to read metering data FROM smart maic device by modbus?

Egidijus 8 месяцев назад в Оборудование обновлен Support Manager 8 месяцев назад 2

Hello,

we would like to read metering data FROM smart maic  by modbus and represent it in building management system. Is it possible?

0
Отвечен

How to create a combined value relay condition?

HR 8 месяцев назад в Общие вопросы обновлен Support Manager 8 месяцев назад 4

How is it possible to create a combined condition for the relay contact at the D103?

I want the relay to close (ON) when Total Power (d.TW) is > than Total Reverse Power (d.TrW) and open (OFF) otherwise