0
Answered

D105-10 Sensors compatible

JochenG 2 years ago in General questions updated by Support Manager 2 years ago 1

Hello,

I am interested in the D105-10. But I wonder which and how many sensors I can use.

- 2 Pulse is clear

- one RS485 (I guess for ONE sensor with that interface? Or only CO2?)

- One DHT22 or five DS18b20

- Anything of the other sensors? I'd guess I can use one with analogue, e.g. light. (or only light?=

GOOD, I'M SATISFIED
Satisfaction mark by JochenG 2 years ago
Answered

Hello,

Yes, you can connect analog sensor also.

Universal meter smart-MAIC D105 has next inputs:

(1) GND (In/Out)

(2) Pulse input 1

(3) Pulse Input 2

(4) 1-Wire Input: One DHT22 or One D280 or five DS18b20 and one Dosimeter

(5) Analog Input 0-18V: Only one analog sensor (Light/Pressure/Depth/TDS/pH/etc)

(6) +5Vdc In/Out

RS485: CO2 sensor or Wind speed sensor or Wind direction sensor

Image 1727